EasyManua.ls Logo

Siemens SINAMICS G220 - Page 541

Siemens SINAMICS G220
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 6722 -
1
Vector control
Field weakening characteristic, Id setpoint (induction motor, p0300 = 1xxx)
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
f
y
0.9
<0.3 s
0
1
1
0
Maximum output voltage [Vrms]
r0071
Flux setpoint
50.0 ... 200.0 [%]
p1570 [D] (100.0)
r0080[0..1]
Torque actual value [Nm]
r0084[0..1]
Flux actual value [%]
Actual motor magnetizing current/short-circuit current [Arms]
r0331 [M]
r0067
Output current maximum [Arms]
r1508
Torque setpoint before
supplementary torque [Nm]
Acceleration starting torque (encoderless)
0.0 ... 200.0 [%]
p1611 [D] (30.0)
Starting torque static (without encoder)
-200.0 ... 200.0 [%]
p1610 [D] (50.0)
+
+
[6060.5]
[6640.3]
Id_set
calculation
Current setpoint smoothing time
4 ... 10000 [ms]
p1616 [D] (40)
Flux setpoint
calculation
[6723.4]
Efficiency optimization
Field weakening
characteristic
1 = Efficiency optimization active
p1401.14 [D]
100 %
Motor rotor time constant / damping time constant d axis [ms]
r0384 [M]
Flux setpoint
selection
r0056
r0056.8
1 = Field weakening active
[2526.4]
Efficiency optimization minimum flux limit value
10.0 ... 200.0 [%]
p3315 [D] (70.0)
Efficiency optimization maximum flux limit value
10.0 ... 200.0 [%]
p3316 [D] (110.0)
1 = Flux setpoint soft starting active
p1401.0 [D]
1 = Flux build-up control active
p1401.2 [D]
1 = Quick magnetizing
p1401.6 [D]
Motor excitation build-up time
-20.000 ... 20.000 [s]
p0346 [M] (0.000)
r0056
r0056.4
1 = Magnetizing completed
[2526.4]
[6723.7]
Quick magnetizing active
Flux setpoint smoothing time
4 ... 5000 [ms]
p1582 [D] (15)
Motor model status
r1751
[6730.4]
[6723.1]
Flux setpoint
Id current limit
Efficiency optimization optimum flux [%]
r3313
Flux threshold value magnetizing [%]
p1573 [D] (100.0)
Field weakening characteristic scaling
80.0 ... 120.0 [%]
p1586 [D] (100.0)
<1>
For vector control without encoder (SLVC).
[6723.1]
[4715.6] r0063[0]
Speed actual value
Unsmoothed [rpm]
Figure14-140 6722 - Field weakening characteristic, Id setpoint (induction motor)
Functions
14.10Closed-loop drive control
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 539

Table of Contents

Related product manuals