- 6799 -
1
Vector control
Display signals
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
r1438
Speed controller speed
setpoint [rpm]
100 ms
100 ms
100 ms
100 ms
100 ms
300 ms
Display values smoothing time constant [ms]
p0045 (4.00)
Display values smoothing time constant [ms]
p0045 (4.00)
√3
r0082[2]
Electric power [kW]
300 ms
100 ms
300 ms
300 ms
100 ms
r0074
Modulation depth [%]
Speed actual value rpm smoothed [rpm]
r0022
Speed setpoint smoothed [rpm]
r0020
Modulation depth smoothed [%]
r0028
Current actual value field-
generating smoothed [Arms]
r0029
Current actual value torque-
generating smoothed [Arms]
r0030
Power factor smoothed
r0038
M
Iq
Display values smoothing time constant [ms]
p0045 (4.00)
p0045
100 ms
Actual torque smoothed [Nm]
r0031
r0032
Active power actual
value smoothed [kW]
r0063[0]
Speed actual value
Unsmoothed [rpm]
r0063[1]
Speed actual value
Smoothed with p0045 [rpm]
r0068[0]
Absolute current actual
value Unsmoothed [Arms]
r0068[1]
Absolute current actual value
Smoothed with p0045 [Arms]
r0082[0]
Active power actual value
(motor) Unsmoothed [kW]
r0063[0]
Speed actual value
Unsmoothed [rpm]
r0078[0]
Current actual value
torque-generating
Unsmoothed [Arms]
r0076[0]
Current actual value
field-generating
Unsmoothed [Arms]
r0080[0]
Torque actual value Unsmoothed [Nm]
r0080[1]
Torque actual value
Smoothed with p0045 [Nm]
r0082[0]
Active power actual value
(motor) Unsmoothed [kW]
r0082[1]
Active power actual value (motor)
Smoothed with p0045 [kW]
r0021
Speed actual value smoothed [rpm]
r0024
Output frequency smoothed [Hz]
r0025
Output voltage smoothed [Vrms]
r0026
DC link voltage smoothed [V]
r0027
Absolute actual current smoothed [Arms]
r0070
Actual DC link voltage [V]
r0072
Output voltage [Vrms]
r0066
Output frequency [Hz]
r0087
Actual power factor
r0072
Output voltage [Vrms]
r0087
Actual power factor
Figure14-148 6799 - Display signals
Functions
14.10Closed-loop drive control
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 547