Figure14-158 Prede󹪝ned and variable quantities for motor e󹪟ciency
In partial load operation of the motor, e󹪟ciency optimization uses the thermal motor model
to continuously determine the dependency between e󹪟ciency and 󹪞ux, and from this it
calculates the optimum 󹪞ux.
,QYHUWHU
7KHUPDOPRWRU
PRGHO
(IILFLHQF\
GHSHQGHQWRQWKH
IOX[
2SWLPXPIOX[
Figure14-159 Calculating the optimum 󹪞ux
E󹪟ciency optimization sets the optimum 󹪞ux in the motor.
)OX[
(IILFLHQF\
)OX[
(IILFLHQF\
(IILFLHQF\RSWLPL]DWLRQLVQRWDFWLYH
(IILFLHQF\RSWLPL]DWLRQLVDFWLYH




Figure14-160 Increasing e󹪟ciency by optimizing the 󹪞ux in the motor
Depending on the operating point of the motor, the 󹪞ux of the reduces or increases.
Parameters
The following list contains the parameters of the "E󹪟ciency optimization" function.