The following list contains the parameters of the "Motor holding brake" function.
Number Name Unit
p0346[0...n] Motor excitation build-up time [s]
c0855[0...n] Unconditionally release holding brake
c0858[0...n] Unconditionally close holding brake
r0899.0...13 Status word sequence control
p1215[0...n] Motor holding brake con󹪝guration
p1216[0...n] Motor holding brake opening time [ms]
p1217[0...n] Motor holding brake closing time [ms]
p1226[0...n] Threshold for zero speed detection [rpm]
p1227[0...n] Zero speed detection monitoring time [s]
p1228[0...n] Pulse cancellation delay time [s]
p1351[0...n] Motor holding brake starting frequency [%]
c1475[0...n] Speed controller torque setting value for motor holding brake