Figure14-202 Time response of the speed monitoring
Example
Examples of how the function can be used:
Gearbox monitoring for traction drives or hoisting gear
Drive belt monitoring for fans or conveyor belts
Blocking protection for conveyor belts
Parameters
The following list contains the parameters of the "Speed deviation monitoring" function.
Number Name Unit
p0490.5 Invert measuring probe or equivalent zero mark
p0580 Measuring probe input terminal
p0581 Measuring probe edge
p0582 Measuring probe pulses per revolution
p0583 Measuring probe maximum measuring time [s]
r0586 Measuring probe speed actual value [rpm]
r0587 Measuring probe measuring time measured
r0588 Measuring probe pulse counter
r0589 Measuring probe wait time
r2169 Actual speed smoothed signals [rpm]
p2181[0...n] Load monitoring response
p2192[0...n] Load monitoring delay time [s]
p2193[0...n] Load monitoring con󹪝guration
c3230[0...n] Load monitoring speed actual value
p3231[0...n] Load monitoring speed deviation [rpm]