NOTICE
Damage to connection plug following incorrect removal
The connection plug may be damaged if the fan unit is removed incorrectly.
• Detach the fan unit connection plug before completely removing the fan unit from the
converter.
The following requirements apply when the fan unit is replaced:
• Comply with ESD regulations.
• Only qualied personnel may replace the fan unit.
• The converter housing cover has been removed.
• Required tools:
– Torx screwdriver T20
Procedure
The procedure for removing and installing the main fan is identical for frame sizes FSD1, FSD2
and FSE. The fan unit diers in terms of the size, the number of fans contained and the number
of xing screws.
The following procedure describes removing and installing the main fan using a converter,
frame size FSD2 as example.
Figure16-4 IP55 main fan, removal
Proceed as follows to remove the fan unit:
1. Release the catch of the connection plug and withdraw the plug upwards.
2. Using a torx screwdriver, release the xing screws of the fan unit and remove the xing
screws.
3. Pull the connection plug through its opening as you slowly lift the fan unit upwards.
Corrective maintenance
16.11Replacing fans
SINAMICS G220 converter
790 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB