Two typical duty cycles are dened to select and dimension a converter to match the
application.
"Low Overload" duty cycle
The "Low Overload" duty cycle ts a uniform
base load with low requirements placed on
brief acceleration phases.
"High Overload" duty cycle
The "High Overload" duty cycle permits dy‐
namic acceleration phases at a reduced con‐
tinuous load.
If not specied otherwise, the power and current data in the technical data always refer to a
duty cycle with Low Overload.
Example
Typical applications for the two duty cycles:
"Low Overload" duty cycle "High Overload" duty cycle
Typical applications when designing accord‐
ing to "Low Overload" include:
• Pumps, fans and compressors
• Wet or dry blasting technology
• Mills, mixers, kneaders, crushers or agita‐
tors
• Basic spindles
• Rotary furnaces
• Extruders
Typical applications when designing accord‐
ing to "High Overload" include:
• Horizontal and vertical conveyor technol‐
ogy, e.g. conveyor belts, roller conveyors,
chain conveyors
• Centrifuges
• Escalators/moving stairways
• Lifting or lowering equipment
• Elevators
• Gantry cranes
• Cable railways
• Storage and retrieval machines
More information
We recommend using the "TIA Selection Tool" conguring software to select the converter.
More information about the "TIA Selection Tool" is available on the Internet: