17.14.3 Current carrying capacity of the braking resistor
Description
The following overview shows examples for the load rating of the braking resistor as a function
of the braking power.
T
T
T
T
1
1
1
U
U
U
T
T
1
NBY
1
NBY
1
NBY
1
NBY
1
U
P
max
Maximum braking power
240 s Cycle time=running time+cooling time
Examples
Rated braking power
Maximum braking power = 20 times the rated braking power
Running time=cycle time/20 12s
Cooling time 228s
Braking power=8 times the rated braking power
Running time=cycle time/8 30s
Cooling time 210s
Braking power=4 times the rated braking power
Running time=cycle time/4 60s
Cooling time 180s
Figure17-9 Load rating of the braking resistor with di󹪜erent braking powers