Field Description
The field is included in the default CDR.
The field is applicable to "CALL_CONNECT", "MEDIA_START", "CALL_
END", and "MEDIA_END" CDR Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "Coder" in the CDR.
The maximum number of characters for Syslog tabular alignment is 15.
Conn ID
[502]
Displays the Digital Connection ID.
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to Gateway CDRs.
The default field title is "ConId" in the CDR.
The maximum number of characters for Syslog tabular alignment is 5.
Connect
Time
[412]
Displays the date and time that the call was connected. The field is a string of
up to 35 characters and in the following format: <hh:mm:ss:ms> UTC <DDD>
<MMM> <DD> <YYYY>. For example, "17:00:49.053 UTC Thu Dec 14 2017"
Note:
To configure the time zone string (e.g., "UTC" - default, "GMT+1" and
"EST"), use the TimeZoneFormat parameter.
The field is included in the default CDR.
The field is applicable only to "CALL_CONNECT" and "CALL_END" CDR
Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The default field title is "ConnectTime" for Syslog and Local Storage, and
"h323-connect-time=" for RADIUS.
The maximum number of characters for Syslog tabular alignment is 35.
Dest Port
[406]
Displays the SIP signaling destination UDP port. The field is an integer of up to
10 digits.
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The default field title is "SigDestPort" for Gateway Syslog and Local
Storage, and "DestPort" for SBC Syslog and Local Storage.
The maximum number of characters for Syslog tabular alignment is 11.
Destination
Host Before
Manipulation
[815]
Displays the original destination hostname (before manipulation, if any).
Note:
The field is optional and can be included in the CDR using the SBC CDR
Format table.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling CDRs.
The maximum number of characters for Syslog tabular alignment is 20.