CHAPTER57 Reporting Information to External Party
Mediant 1000 Gateway & E-SBC | User's Manual
Field Description
[606] Note:
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is empty for RADIUS (ACCT_INPUT_OCTETS
standard ID 42).
The maximum number of characters for Syslog tabular alignment is 10.
Local Input
Packets
[604]
Displays the number of packets received by the device. The field is an integer
from 0 to 0XFFFFFFFF.
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "InPackets" for Syslog and Local Storage, and
empty for RADIUS (ACCT_INPUT_PACKETS).
The maximum number of characters for Syslog tabular alignment is 10.
Local Jitter
[610]
Displays the RTP jitter. The field is an integer from 0 to 40000 samples (-1 if
unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "RTPjitter".
The maximum number of characters for Syslog tabular alignment is 9.
Local MOS
CQ
[627]
Displays the local MOS for conversation quality. The field is an integer from 10
to 46 (127 if information is unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "LocalMosCQ".
The maximum number of characters for Syslog tabular alignment is 10.
Local Output
Octets
[607]
Displays the local output octets (bytes).
Note:
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.