CHAPTER58 Syslog and Debug Recording
Mediant 1000 Gateway & E-SBC | User's Manual
● If you want to configure a Log Filter rule that logs Syslog messages to a Syslog
server (i.e., not to a Debug Recording server), you must enable Syslog
functionality, using the 'Enable Syslog' (EnableSyslog) parameter (see Enabling
Syslog). Enabling Syslog functionality is not required for rules that include Syslog
messages in the debug recording sent to the Debug Recording server.
● To configure the Syslog server's address, see Configuring the Syslog Server
Address. To configure additional, global Syslog settings, see Configuring Syslog.
● To configure the Debug Recording server's address, see Configuring the Debug
Recording Server Address.
● To configure additional, global CDR settings such as at what stage of the call the
CDR is generated (e.g., start and end of call), see Configuring CDR Reporting.
The following procedure describes how to configure Log Filter rules through the Web interface. You
can also configure it through ini file [LoggingFilters] or CLI (configure troubleshoot >
logging logging-filters).
➢ To configure a Log Filter rule:
1. Open the Logging Filters table (Troubleshoot menu > Troubleshoot tab > Logging folder >
Logging Filters).
2. Click New; the following dialog box appears:
3. Configure a Log Filtering rule according to the parameters described in the table below.
4. Click Apply.
Table 58-1: Logging Filters Table Parameter Descriptions
Parameter Description
'Index'
[LoggingFilters_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
'Filter Type'
filter-type
[LoggingFilters_
FilterType]
Defines the filter type criteria.
■ [1] Any= (Default) Debug recording is done for all calls.
■ [2] Trunk ID = Filters log by Trunk ID.
Note: Applicable only to the Gateway application.
- 1035 -