CHAPTER68 Configuration Parameters Reference
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
no-alarm-for-disabled-port
[NoAlarmForDisabledPort]
Enables the device to not send the SNMP
trap acBoardControllerFailureAlarm alarm.
This alarm indicates a "disabled" telephony
port, which is one that is not configured at all
or that is configured but without a Trunk
Group ID (i.e., Trunk Group ID is 0), in the
Trunk Group table.
â– [0] = (Default) Disabled. The device
sends the SNMP trap for non-configured
ports.
â– [1] = Enabled. The device does not send
the SNMP trap for non-configured ports.
Note:
â– The parameter is applicable to all
telephony (analog and digital) port
types.
â– The parameter is applicable only to the
Gateway application.
configure voip > gateway analog
fxs-setting fxs-offhook-timeout-
alarm
[FXSOffhookTimeoutAlarm]
Defines the duration (in seconds) of an FXS
phone in off-hook state after which the
device sends the SNMP alarm,
acAnalogLineLeftOffhookAlarm. The device
starts this timer once the reorder tone begins
playing when the phone goes off-hook. The
alarm is cleared when the phone's hook-
flash button is pressed or the phone returns
to on-hook state.
The valid value is 0 to 180,000. The default
is 0, meaning that this alarm is not sent
when the phone goes off-hook.
Note:
â– The parameter is applicable only to FXS
interfaces.
â– The parameter's setting is applied only
to phones that go off-hook after you have
configured the parameter.
configure system > snmp settings
> engine-id
[SNMPEngineIDString]
Defines the SNMP engine ID for
SNMPv2/SNMPv3 agents. This is used for
authenticating a user attempting to access
the SNMP agent on the device.
The ID can be a string of up to 36
characters. The default is
00:00:00:00:00:00:00:00:00:00:00:00 (12
Hex octets characters). The provided key
must be set with 12 Hex values delimited by
a colon (":") in the format xx:xx:...:xx. For
example,
00:11:22:33:44:55:66:77:88:99:aa:bb
- 1102 -