CHAPTER18 Core Entities
Mediant 1000 Gateway & E-SBC | User's Manual
Table 18-4: SIP Interfaces table Parameter Descriptions
Parameter Description
'SRD'
srd-name
[SIPInterface_SRDName]
Assigns an SRD to the SIP Interface.
If only one SRD is configured in the SRDs table, the
SRD is assigned to the SIP Interface by default. If
multiple SRDs are configured in the SRDs table, no
value is defined and you must assign an SRD.
To configure SRDs, see Configuring SRDs.
Note:
â–  The parameter is mandatory.
â–  You can assign the same SRD to multiple SIP
Interfaces (SBC and Gateway).
General
'Index'
[SIPInterface_Index]
Defines an index for the new table row.
Note: Each row must be configured with a unique
index.
'Name'
interface-name
[SIPInterface_InterfaceName]
Defines a descriptive name, which is used when
associating the row in other tables.
The valid value is a string of up to 40 characters. By
default, if you do not configure a name, the device
automatically assigns the name "SIPInterface_<row
index>" (e.g., "SIPInterface_1" when added to Index
1).
Note: The parameter value cannot contain a forward
slash (/).
'Topology Location'
topology-location
[SIPInterface_TopologyLocation]
Defines the display location of the SIP Interface in
the Topology view in the Web interface.
â–  [0] Down = (Default) The SIP Interface element
is displayed on the lower border of the view.
â–  [1] Up = The SIP Interface element is displayed
on the upper border of the view.
For more information on the Topology view, see
Building and Viewing SIP Entities in Topology View.
'Network Interface'
network-interface
[SIPInterface_NetworkInterface]
Assigns an IP network interface (Control-type) to the
SIP Interface.
By default, no value is defined.
To configure network interfaces, see Configuring IP
Network Interfaces.
Note: The parameter is mandatory.
'Application Type'
application-type
[SIPInterface_ApplicationType]
Defines the application for which the SIP Interface is
used.
â–  [0] GW = (Default) Gateway application.
â–  [2] SBC = SBC application.
- 333 -