AudioCodes Mediant 8000 - Fiber Optic Cables; Figure 19-1: SFP Modules and Their Locks

AudioCodes Mediant 8000
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation & Operation Manual 124 Document # LTRT-92224
Mediant 8000
Figure
19-1: SFP Modules and Their Locks
19.1.2 Fiber Optic Cables
Twin single-mode fiber optic cables with Dual-LC plug must be connected to the PSTN
transceivers 1A and 1B on the 6310/RTM module in the rear of the chassis. For PSTN
interface redundancy, it is recommended to connect two STM-1/OC-3 links to each
6310/RTM module.
Care in Handling Fiber Optic Cabling
When handling the fiber optic cables, be sure to note the following:
Excessive bending of the Fiber Optic Cable can cause distortion and signal
losses
Ensure you abide by the minimum bending radius recommended by the Fiber
Optic Cable supplier
Maximum Fiber Optic Cable length for multi-mode fiber is 2 km
Maximum Fiber Optic Cable length for single-mode fiber is 22 km