21.4 Configuring Connectivity with the EMS Server
After the Mediant 8000 software on both SC boards is up and running, you must
configure connectivity between the Mediant 8000 and the EMS Server. This action is
performed by running the command tools ems on the CLI interface of the Active SC
board. For more information, refer to 'Configuring Connectivity between Media
Gateway and EMS Server' on page 171.
Once you have completed this configuration, open the EMS client, establish
connection with the EMS server and verify that the Mediant 8000 Media Gateway is
visible in the EMS Media Gateways tree and its main status screen is correctly
displayed. Verify the status of all Mediant 8000 components (SC boards, ES boards,
power supplies, fan modules etc). Perform lock/unlock action on any board (e.g.
standby ES board) and verify that actions are executed as expected and alarms are
properly recorded in the EMS alarms browser.