Installation & Operation Manual 256 Document # LTRT-92224
Mediant 8000
Table 28-1: Redundancy Group Parameters
Parameter Name Type
Provisioning
Type
Description
Redundancy
Mode
Enum
Not Protected,
Hot, Warm
Instant Defines the Desired Redundancy mode
for all Media Gateway boards assigned to
this group.
ï‚§ The Actual Redundancy mode for
each Media Gateway board may never
be higher than the value indicated by
this parameter. Therefore this
parameter may be used to force warm
or not protected redundancy modes on
all Media Gateway boards.
Protected Boards String
Up to 80 chars
Read-Only Indicates all Normal Media Gateway
boards currently associated with this
Redundancy Group.
Redundant Board String
Up to 80 chars
Read-Only Indicates the Redundant Media Gateway
board that is currently associated with this
Redundancy Group.
Redundant Board
In Use
Enum
Unused, Used
Read-Only Indicates whether the Redundant board is
currently used for back-up of a specific
normal board.
Failed Board Integer
-1 – 19
Read-Only Indicates the number of the failed Media
Gateway boards that are currently being
backed-up by the Redundant board.
Failed Board
Behavior
Enum
Recover Service,
Stop Service,
Debug Mode
Instant Defines the default behavior in case of
Media Gateway board failure. The
following values are available:
 Recover Service – attempts to
recover service provided by the failed
board by performing switchover to the
Redundant board (if it's available) or
restarting the failed board.
 Stop Service – keep the failed board
reset until the user manually attends to
it, solves the problem (e.g. by
replacing the board) and performs
UNLOCK action)
 Debug Mode –special mode used for
debugging the redundancy
mechanism; suitable for lab
environment only.
Detection Time
For Hot
Enum
Normal, Extra
Instant Defines the failure detection time for
boards that have the Actual Redundancy

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 8000 and is the answer not in the manual?

AudioCodes Mediant 8000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 8000
CategoryGateway
LanguageEnglish

Related product manuals