Version 6.6 539 October 2014
Installation & Operation Manual 39. Configuring the Media Settings
39.1 DSP Templates
The Media Gateway board may be configured to work with up to two DSP templates
simultaneously. Each DSP template supports specific voice coders, channel capacity
and features.
Note: For the list of supported DSP templates and detailed specification of each
DSP template, refer to LTR-90XXX Mediant 5000 and 8000 Release Notes.
A Single DSP template may be configured via the DSP Template Number parameter
as described in the previous section. Multiple DSP templates must be defined via the
DSP Template objects as described below.
To add and configure the DSP Template:
1. Click
to access the Media Gateway status screen.
2. In the Navigation Pane, select Media
DSP Templates; the DSP Templates list
is displayed.
3. Use the
or buttons to add or remove entries.
4. Select a specific row and then in the configuration pane, click DSP Template
Settings; the DSP Template Settings screen is displayed.
5. Configure the DSP Template parameters according to the table 'DSP Template
Settings' below.
6. Click the Maintenance icon
and select Unlock to activate the configuration.
Table
39-9: DSP Template Settings
Parameter Name Type Provisioning Type Description
DSP Template Number Enum
G723(0), AMR(1),
EVRC(2), iLBC(3),
AMRWB(4),
EVRCB(5),
G729EV12(6),
EG711iLBC(7),
G729EV32(8),
RTANB(9),T38Ver3(1
0), RTAWB(11)
Online Defines the DSP
template to be used by
the Media Gateway
board. Each DSP
template supports
specific voice coders,
channel capacity and
features.