Version 6.6 905 October 2014
Installation & Operation Manual C. Appendix: Testing Installation and Basic Configuration
C Appendix: Testing Installation and
Basic Configuration
The below test plan should be used after installing a new Media Gateway to assure
the following:
Media Gateway hardware is OK and was installed properly
Media Gateway’s basic configuration was successfully completed
It is recommended to integrate the below test plan as a component of the Acceptance
Test Plan (ATP). The Media Gateway is a component of the complete ATP solution.
The ATP is typically developed by the solution integrator and covers all solution
components (e.g. Softswitch, Media Gateway, IP routers etc). The ATP typically
verifies “end to end” functionality, for example, the calls running through the solution.
The below test plan should be integrated in the ATP as part of this “end to end”
functionality testing (e.g. you may send and receive calls through the Media Gateway,
perform Media Gateway board switchover and then verify that calls are recovered on
the redundant board).
Prior to running the tests described below, the tester should have a basic
understanding of how to operate the product. Adjacent to each test case there is a
reference to the relevant chapter in the documentation. The tester should read these
chapters to acquire the required tools to run this test. Running this test can also be
considered as an excellent initial hand’s-on training session.
Table
C-1: Test Procedures
# Test Title Test Description Reference
1 Verify the
connectivity between
the EMS and the
Media Gateway.
Open EMS client. Select Media
Gateway in the MG Tree. Verify that
Media Gateway status screen is
displayed.
Lock and Unlock Media Gateway.
Verify that the appropriate changes to
Administrative State alarms are
displayed in the EMS alarms screen.
'Configuring Connectivity
between Media Gateway
and EMS Server' on page
171
2 Verify the NTP
server configuration.
Verify that all provisioned NTP servers
are Unlocked and Enabled.
Open “NTP Server” status screen.
Verify that at least one NTP server is
provisioned (for simple installations
EMS server may be used as NTP
Server).
'Time and Date
Configuration' on page
262
3 Verify the timezone
configuration.
Connect to the CLI interface on both
Active and Standby SC boards. Run
date command. When both NTP Server
and Timezone are properly configured,
the date command should output
correct time and date.
'Time and Date
Configuration' on page
262