Version 6.6 463 October 2014
Installation & Operation Manual 38. Configuring the PSTN Subsystem
38.3 Configuring T3 Interfaces
Three T3 interfaces are provided on each TP-6310 Media Gateway board for
connecting to the PSTN network. These interfaces are available on the 6310/RTM
modules, located on the back of the Mediant 8000 chassis, behind the corresponding
TP-6310 Media Gateway boards. For additional details, see Section 'TP-6310 Media
Gateway Board' on page 45 and '6310/RTM - Rear Transition Module' on page 49.
Configuration and fault monitoring of T3 interfaces is performed as follows.
To view status of the T3 interfaces on a specific Media Gateway board:
1. Click
to access the Media Gateway status screen.
2. Select the specific Media Gateway board.
3. In the Navigation pane, select PSTN
DS3; the DS3 Status screen is displayed.
Figure
38-4: DS3 Status Screen
4. To view the detailed list and status of T1 trunks, corresponding to the specific T3
interface, double-click the line that corresponds to the specific T3 interface.
The E1/T1 Trunks status screen, containing relevant trunks, is displayed. For
more information, see Section 'Configuring the E1/T1 Trunks'.
To configure a T3 Interface on specific Media Gateway board:
1. Access the DS3 Status screen, as described above.
2. In the DS3 Status screen, select a T3 interface and then in the configuration
pane, click DS3 Settings; the DS3 Settings screen is displayed.
3. Modify parameters as described in the table 'T3 Interface Properties' below.