Installation & Operation Manual 45. Hardware Replacement
45.6.3 Troubleshooting the ES/6600 Board Installation
If the Operational State of the replaced ES board remains Disabled (the board is
displayed Red in the EMS) 10 minutes after inserting the board into the chassis, use
the procedure below to restore service on the replaced ES board.
Note: The procedure described below configures a temporary IP address for the
replaced ES board. This IP address is used only for the recovery of the ES board
after a malfunction. As soon as the full service on the ES board is restored, the
provisioned IP address becomes invisible to the other equipment in the IP network.
To configure a temporary IP address on the ES board:
1. Connect to the Switch Board's RS232 console.
2. Log in using the username: admin and password: password.
Escape character is '^]'.
PTI CPC6600 (from application)...
login: admin
Password: password
#
3. Configure the IP address on Ethernet Switch board (This configuration does not
survive reset, hence you should immediately proceed to the software installation
as described above).
# ip config sw0 10.1.1.35
4. In the EMS, open the ES board's Provisioning Screen and provision the same IP
address as configured in the previous step. For more information, see Section
'Working with the Ethernet Switch Boards' on page 261.
5. Lock and unlock the ES board.
6. The ES board is reset and new software files will be loaded on it. After 10
minutes, the ES board should complete the restart and restore its service. When
this occurs, ES board’s Operational State is changed to Enabled.