33.18.4.2 CLI User Synchronization with the EMS Server
CLI users synchronization may be enabled or disabled via the CLI interface on the
Active SC board. Root privileges are required to modify the CLI users synchronization
mode.
To enable CLI user Synchronization:
1. Connect to the CLI interface on the Active SC board. For more information, see
Section 'Command Line Interface' on page 107.
2. Login as root user. For more information, see Section 'Logging in as a Root User'
on page 115.
3. At the prompt, type tools user sync and press Enter. The SYNCHRONIZE CLI
USERS WITH EMS menu appears.
SYNCHRONIZE CLI USERS WITH EMS
enable_block—ENABLE BLOCK MODE:
Synchronize CLI and EMS users databases.
Block access to CLI for users with expired credentials.
enable_7days—ENABLE 7 DAYS MODE:
Synchronize CLI and EMS users databases.
Allow access to CLI for users with expired credentials
for additional 7 days.
disable—DISABLE
Do not synchronize CLI and EMS users databases.
CLI users should be managed via 'tools user' script.
4. At the Choose submenu prompt, choose the desired synchronization option and
press Enter.
Choose submenu : enable_block
current mode is 'disable'
changing mode to enable_block
done
The synchronization mode is configured and immediately activated. If
synchronization is enabled, the CLI users database will be synchronized with the
EMS server within the next few minutes.