Table 39-10: AMR Coder Profile Settings
Parameter Name Type Provisioning Type Description
Profile Name String
Up to 40 chars
Instant Defines a textual
name of the AMR
Coder Profile
enabling user to
easily identify it.
Referenced By String
Up to 255 chars
Read-Only Indicates VoP
boards associated
with this AMR
Coder Profile.
Table 39-11: AMR Coder Policy Settings
Parameter Name Type Provisioning Type Description
Rule Name String
Up to 20
chars
Instant Defines a textual name for the
AMR Codec Policy enabling user
to easily identify it.
Current Rate Integer
0 – 8
Read-Only Indicates the current AMR Rate.
Current
Redundancy Level
Integer
0 – 3
Read-Only Indicates the current Redundancy
Level.
Current Threshold Integer
0 – 63
Read-Only Indicates the current Frame Loss
Ratio (FLR) threshold.
Current Hysteresis Integer
0 – 15
Read-Only Indicates the current Hysteresis of
FLR threshold.
Rate Integer
0 – 8
Online Defines the new AMR Rate. Upon
successful Unlock action, this
value is copied to the Current
Rate parameter and applied to all
related boards.
Redundancy Level Integer
0 – 3
Online Defines the new Redundancy
Level. Upon successful Unlock
action, this value is copied to the
Current Redundancy Level
parameter and applied to all
related boards.