EasyManua.ls Logo

AudioCodes Mediant 8000 - Channelized T3

AudioCodes Mediant 8000
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation & Operation Manual 464 Document # LTRT-92224
Mediant 8000
Table 38-3: T3 Interface Properties
Parameter Name Type
Provisioning
Type
Description
DS3 Name String
Up to 20 chars.
Instant Defines textual name for the DS3 Interface
enabling user to easily identify it.
DS3 Clock
Source
Enum
Slave, Master,
LocalPLL
Instant Defines the clock source for the specific
DS3 interface. See Section 'Timing Module
Line Sync Clock Mode' on page 522 for
details.
DS3 Framing
Method
Enum
M23, C-bitParity
Instant Defines the framing method for DS3
interface.
DS3 Line Build
Out
Enum
672mv, 744mv,
816mv, 888mv,
960mv, 1008mv
Instant Defines the build-out voltage (in mili-volts)
for DS3 interface.
38.3.1 Channelized T3
In “channelized T3” configuration, T3 interfaces are carried inside the OC-3 (SONET)
optical links. Up to three T3 trunks can be channelized. To configure channelized T3
trunks, configure the Fiber Group as follows:
Fiber Group Interface Type = OC3
Fiber Group Mapping Type = STS1ofDS3
See Table 'PSTN Fiber Group Properties’ for details.
In contrast to the regular T3 coaxial interfaces, “channelized T3” configuration benefits
from the APS protection provided by the OC-3 (SONET) optical links.
In a “channelized T3” configuration, both the OC-3 PSTN Fiber Group Status Screen
(as shown in ‘Figure : OC-3 PSTN Fiber Group Status Screen) and the DS3 Status
Screen (as shown in ‘Figure DS-3 Status Screen) are accessible.
Configuration is also supported for both the PSTN Fiber Group and the T3 Interface,
as described in the previous sections.

Table of Contents