Installation & Operation Manual 280 Document # LTRT-92224
Mediant 8000
31.5 Endpoint Name Provisioning
This section describes the endpoint name provisioning.
31.5.1 Physical Terminations
The Physical Terminations are provisioned via the Phys Term Name Pattern
parameter that contains the Endpoint Name template. Indexes (e.g. Board#, Trunk#
and Channel#) are indicated in the template by * (asterisk) character. The exact
meaning of each * (asterisk) character is determined according to the Phys
Termination Type and Include Board Index parameters as follows:
When Include Board Index parameter is set to Yes, the first * (asterisk)
character is substituted by Board#
Remaining * (asterisk) characters are substituted according to the Phys Termination
Type parameter as follows:
Table
31-1: Physical Termination Types
Phys Termination Type Pattern Substitution
TGW: Trunk TS The pattern should contain two additional *
(asterisk) characters to be substituted by
Trunk# and Channel# accordingly.
TGW: T3 Trunk TS The pattern should contain three additional *
(asterisk) characters to be substituted by DS3
Interface#, Trunk# and Channel# accordingly.
V5.2: Interface Port The pattern should contain two additional *
(asterisk) characters to be substituted by V5.2
Interface# and Port# accordingly.
V5.2: SubRack Card Port The pattern should contain three additional *
(asterisk) characters to be substituted by V5.2
SubRack#, Card# and Port# accordingly.
Division of V5.2 ports into "cards" and "sub-racks"
is performed according to the "max count" values
set in the MGC Pattern Level table for Port# and
Card# indexes, as described below.
The starting number (offset) and maximum count of Trunk#, Channel# and other
"index" elements can be controlled via the MGC Pattern Level table, located in the
same provisioning frame. The table is populated with entries, according to the value of
Phys Termination Type parameter and is updated when Apply button is clicked.