Page #281 background imageLoading...
Page #281 background image
Version 6.6 281 October 2014
Installation & Operation Manual 31. Configuring the MGCP/MEGACO Protocols
31.5.2 Ephemeral Terminations (for MEGACO only)
Ephemeral Terminations are provisioned via the MEGACO RTP Term Name
Pattern parameter. Indexes (Board# and Termination#) are indicated in template by
the * (asterisk) character.
At least one * characters should be present in the template to be substituted by
Termination#.
If the template contains two * characters the 1
st
* is substituted by Board#.
The starting number of Termination# can be controlled via the MEGACO RTP Term
Offset parameter.
31.5.2.1 Example 1
Phys Term Name Pattern = ds/e1-*/*
Include Board Index = "no"
Phys Termination Type = "TGW: Trunk TS"
Trunk# Offset = 1
TS# Offset = 1
Endpoint name (board 8, trunk 2, channel 10): ds/e1-2/10
31.5.2.2 Example 2
Phys Term Name Pattern = BR*/TR*/TS*
Include Board Index = "yes"
Phys Termination Type = "TGW: Trunk TS"
Trunk# Offset = 1
TS# Offset = 1
Endpoint name (board 8, trunk 2, channel 10): BR8/TR2/TS10
31.5.2.3 Example 3
Phys Term Name Pattern = al/*/*/*
Include Board Index = "no"
Phys Termination Type = "V5.2: SubRack Card Port"
SubRack# Offset = 1
Card# Offset = 1
Card# Max Count = 10
Port# Offset = 1
Port# Max Count = 10
Endpoint name (board 8, V5.2 port# 123): al/1/2/3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 8000 and is the answer not in the manual?

AudioCodes Mediant 8000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 8000
CategoryGateway
LanguageEnglish

Related product manuals