45.6.2 Replacing the Ethernet Switch RTM Module
This section describes how to replace the Ethernet Switch RTM module.
 To remove an Ethernet Switch RTM from the chassis:
1. In the EMS, lock the Ethernet Switch board of the RTM to be replaced. For more
information see 'Working with the Ethernet Switch Boards' on page 261.
2. Remove the connected cables.
3. Unfasten the screws on the plate of the board.
4. Pull on the two ejector/injector latches and ease out the board from the slot.
 To insert an Ethernet Switch RTM into the chassis:
1. Hold the board Vertical with the top of the board pointed upward.
2. With the black ejector/injector latches in the open (pulled out) position, insert the
board in the slot, aligning the board on the grooves on each end.
3. Ease the board all the way into the slot until the ejector/injector latches touch the
chassis.
4. Press the two black ejector/injector latches on both ends inward, toward the
middle until you hear a click.
5. Fasten the screws on the front plate of the board to secure the board to the
chassis and to ensure that the board has an earth connection to the chassis.
6. Reconnect the cables according to the IP Separation configuration. See Section
'Ethernet Switch Boards' on page 72.
7. In the EMS, unlock the Ethernet Switch board of which the RTM has been
replaced. For more information, see Section Section 'Working with the Ethernet
Switch Boards' on page 261.
8. In the EMS, verify that the Ethernet Switch board’s Operational State is
Enabled.
9. In the EMS, double Click the Ethernet Switch board of the RTM that has been
replaced. In the status screen that appears, verify that the uplink port's
Operational State is Enabled.