Parameter Name Type
Provisioning
Type
Description
Trunk ID Integer
0-84
Online Relevant for Layer2Type=MTP2 only.
Defines the ID of the trunk used for carrying
the SS7 signaling messages.
Time Slot
Number
Integer
0-31
Online Relevant for Layer2Type=MTP2 only.
Defines the ID of the timeslot used for
carrying the SS7 signaling messages.
MTP2 Profile ID Integer
0-3
Online Relevant for Layer2Type=MTP2 only.
Defines the ID of the MTP2Profile that
contains timers and basic MTP2 layer
configuration for specific SS7 Data Link.
Multiple SS7 Data Links may use the same
MTP2 Profile.
Congestion Low
Mark
Integer
0-255
Online Relevant for Layer2Type=MTP2 only.
Defines the low threshold of the congestion
mark on the SS7 Data Link. When the
transmit queue of a congested link contains
less than the 'Low Mark' messages, a
congestion condition no longer exists.
Congestion High
Mark
Integer
0-255
Online Relevant for Layer2Type=MTP2 only.
Defines the high threshold of the congestion
mark on the SS7 Data Link. When a link
contains more than the 'High Mark'
messages on the transmit queue, the link is
congested.