Version 6.6 93 October 2014
Installation & Operation Manual 15. Site Preparation
Item Requirement
E1/T1 cables (for TP-8410 boards):
E1/T1 cables are used for connecting each E1/T1 trunk interface
on the TP-8410 board with the PSTN equipment. Shielded cables
are required for NEBS GR-1088-CORE compliance. For a detailed
specification of E1/T1 cables see 'Connecting the E1/T1 PSTN
Cables (TP-8410 Boards)' on page 58.
15.2.1 E1/T1 Cables for TP-8410
If you use the Mediant 8000 with TP-8410 boards, provide two cables for connecting
E1/T1 trunks to each TP-8410 board – one with the 100-pin SCSI connector and
another with the 68-pin SCSI connector.
Note : E1/T1 cables are not supplied with the system and should be provided by
customer.
The cables should match the following requirements:
Cable: 26 AWG (100 to 120 Ohm) cable.
Connector: see 'TP-8410/RTM E1/T1 Trunk Connectors' on page 58
Table 15-3: Recommended E1/T1 Cable Parts for TP-8410 Board
Part Description No. of Pins Part # Supplier
Male Connector 1.27 mm Cable
Plug
68 R-ZI-013068 All Best
Electronics
Co Ltd.
100 R-ZI-013100
Cable Hood or Shroud 0.050 Series
Backshell
68 R-ZC-013068-S3
100 R-ZC-013100-S