EasyManua.ls Logo

AudioCodes Mediant 8000 - SC Boards in the EMS; Figure 27-1: SC Boards in EMS

AudioCodes Mediant 8000
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation & Operation Manual 224 Document # LTRT-92224
Mediant 8000
27.2 SC Boards in the EMS
In the EMS, the Active SC board is colored black, while the Standby SC board is
colored blue-gray. The SC board in slot 1 is initially the Active SC board (upon chassis
power up) and the SC board in slot 2 is initially the Standby SC board.
Figure
27-1: SC Boards in EMS
The status of the SC boards is represented by a standard Operational State,
Administrative State and Severity attributes.
When the SC board is functioning properly, its Operational State is set to
Enabled , Severity is set to Clear and in the EMS, the SC board is colored green.
When the SC board’s functionality is degraded, an alarm indicating the problem
details is generated and board’s Severity is set according to the alarm’s severity.
In the EMS board is colored blue, yellow or orange, according to the Severity
value.
When the SC board is not functioning properly (or is absent), its Operational
State is set to Disabled and in the EMS, the SC board is colored red.
When the SC board is locked, its Administrative State is set to Locked and in
the EMS, the SC board is colored grey.