Installation & Operation Manual 426 Document # LTRT-92224
Mediant 8000
Low Freq Level [-dBm] – The generation level 0 dBm to -31 dBm.
High Freq Level [-dBm] – The generation level. 0 to -31 dBm. The value is zero
(0) for a single tone.
Default Duration [msec] - The default duration (in 1 msec units) of the
generated tone.
37.2.1.3 Default Configuration
The following table describes the default Call Progress Tones configuration of the
Media Gateway boards:
Table
37-2: Default Call Progress Tones
[NUMBER OF CALL PROGRESS TONES]
Number of Call Progress Tones=9
#Dial tone
[CALL PROGRESS TONE #0]
Tone Type=1
Tone Form = 1 (Continuous)
Low Freq [Hz]=350
High Freq [Hz]=440
Low Freq Level [-dBm]=13 (-13dBm)
High Freq Level [-dBm]=13
First Signal On Time [10msec]=300
#Dial tone
[CALL PROGRESS TONE #1]
Tone Type=1
Tone Form = 1 (Continuous)
Low Freq [Hz]=440
High Freq [Hz]=0
Low Freq Level [-dBm]=10 (-10dBm)
High Freq Level [-dBm]=0
First Signal On Time [10msec]=300
#Ringback
[CALL PROGRESS TONE #2]
Tone Type=2
Tone Form = 2 (Cadence)
Low Freq [Hz]=440
High Freq [Hz]=480
Low Freq Level [-dBm]=19 (-19dBm)
High Freq Level [-dBm]=19
First Signal On Time [10msec]=200
First Signal Off Time [10msec]=400
#Ringback
[CALL PROGRESS TONE #3]
Tone Type=2
Tone Form = 2 (Cadence)
Low Freq [Hz]=440
High Freq [Hz]=0