# Test Title Test Description Reference
4 Verify the state of
the Media Gateway
Open Media Gateways status screen.
In the Information Pane, verify the
following:
Administrative State is Unlocked
Operational State is Enabled
'Configuring & Operating
the Media Gateway' on
page 155
5 Verify the state of
the SC boards.
Select 1
st
SC board in the Media
Gateway’s status screen. In the
Information Panel, verify the following:
Administrative State is Unlocked
Operational State is Enabled
Repeat the above steps for the 2
nd
SC
board.
'Working with the SC
Boards' on page 223
6 Verify the SC board
switchover
Perform “Switch Over” maintenance
action on the active SC board (the one
with the grey background in the EMS
GUI). Verify that SC switchover has
successfully completed (another SC
board should become active).
Wait till the initially-active SC board
returns to service (it’s state changed to
Unlocked/Enabled). Perform “Switch
Backmaintenance action. Verify that
activity switches back to initially-active
SC board.
'Working with the SC
Boards' on page 223
7 Verify the state of
the ES boards
Select 1
st
ES board in the Media
Gateway's status screen. In the
Information Panel, verify the following:
Administrative State is Unlocked
Operational State is Enabled
Verify that the status of all uplinks,
connected to the 1
st
ES board, is
Unlocked / Enabled with no alarms
(uplink are displayed on the ES board’s
panel in the EMS status screen; uplinks
in correct state are color-coded
“green”)
Repeat the above steps for the 2
nd
ES
board.
'Working with the ES
Boards' on page 261