Version 6.6 907 October 2014
Installation & Operation Manual C. Appendix: Testing Installation and Basic Configuration
# Test Title Test Description Reference
8 Verify the ES board
switchover
Disconnect uplink on the active ES
board (the one with grey background in
the EMS GUI). Verify connectivity
between the EMS server and Media
Gateway (Media Gateway is still visible
in the EMS GUI). Verify that ES board’s
activity switchover is performed
(another ES board should become
active).
Re-connect uplink to the ES board.
Perform the “Align To Me” maintenance
action on the “initially active” ES board.
Verify that ES switchover is properly
completed (initially-active ES board
should become active).
'Working with the ES
Boards' on page 261
9 Verify the state of
the Media Gateway
boards
Select 1
st
Media Gateway board in the
Media Gateway’s status screen. In the
Information Panel, verify the following:
Administrative State is Unlocked
Operational State is Enabled
Double-click the Media Gateway board
and verify the state of it’s PSTN links
and trunks. All physically connected
links and trunks should be
Unlocked/Enabled. The rest of the
links/trunks should be Locked.
Repeat the above steps for all available
Media Gateway boards.
'Working with the Media
Gateway Boards' on page
245
10 Verify the state of
the Media Gateway
board’s redundancy
Note: this test is applicable only to the
configurations where redundant Media
Gateway board is available.
Open Redundancy provisioning screen.
In the Redundancy TP List tab, verify
that both Protection Required and
Redundant Mode states for all non-
redundant Media Gateway boards are
hot.
'Working with the Media
Gateway Boards' on page
245