14. After all basic configuration parameters are prompted, a summary of the settings
is displayed.
Configuration Summary:
Global SC IP Address : 10.7.13.90
1
st
SC IP Address : 10.7.13.91
2
nd
SC IP Address : 10.7.13.92
Time Zone : Europe/Paris
Enable Security : 0 (no)
SC Root Password : ******
Product Type : 0 (Mediant 8000)
15. You are prompted to start configuring. To commence the configuration, type y
and press Enter.
Start configuring ([y]/n) [n]: y
>>> Configure INET services ...
>>> Update /etc/inet/inetd.conf file ...
>>> Restore file /etc/inet/inetd.conf from the backup ...
>>> Update /etc/inet/services file ...
(This sequence is abbreviated)
16. After the installation successfully completes the SC software configuration, it will
determine whether OS Patches need to be installed on the specific SC board.
OS patches installation ensures that the latest operating system’s security and
stability fixes are applied. It also ensures that the Mediant 8000 software operates
in the same well-defined software environment that was used during the software
verification and validation process.
When prompted to start the OS patches installation, type y and press Enter.
>>> Install OS patches ...
SC software contains new OS patches that must be installed.
Installation of OS patches may take considerable time.
However without these OS patches, SC software may not function
properly and/or SC security may be compromised.
Install OS patches? (y/n) [y]: y
Applying 112785-65 (1 of 25) ... done
Applying 112837-16 (2 of 25) ...
(This sequence is abbreviated)