Installation & Operation Manual 424 Document # LTRT-92224
Mediant 8000
8. Confirmation Tone
9. Call Waiting Tone
Tone Modulation Type – The tone can be either Amplitude Modulated (1) or
regular (0).
Tone Form – The format of the tone can be one of the following indices:
• Continuous
• Cadence
• Burst
Low Freq [Hz] – The frequency in Hertz of the lower tone component for a dual
frequency tone, or the frequency of the tone for a single tone. This parameter is
relevant only in case the tone is not Amplitude Modulated.
High Freq [Hz] – The frequency in Hertz of the higher tone component for of a
dual frequency tone, or zero (0) for a single tone. This parameter is relevant only
in case the tone is not modulated.
Low Freq Level [-dBm] – The generation level 0 dBm to -31 dBm. This
parameter is relevant only when the tone is not Amplitude Modulated.
High Freq Level [-dBm] – The generation level. 0 to -31 dBm. The value is zero
(0) for a single tone. This parameter is relevant only when the tone is not
Amplitude Modulated.
First Signal On Time [10 msec] – The “Signal On” period (in 10 msec units) for
the first cadence ON-OFF cycle, for cadence tone. When a tone is configured to
be continuous, this parameter defines the tone On event detection time. When a
tone is configured to be burst tone, it defines the tone’s duration.
First Signal Off Time [10 msec] – The “Signal Off” period (in 10 msec units) for
the first cadence ON-OFF cycle, for cadence tone. In case of burst tone, this
parameter defines the off time required after burst tone ended until the tone
detection is reported. For a continuous tone, this parameter is ignored.
Second Signal On Time [10 msec] – The “Signal On” period (in 10 msec units)
for the second cadence ON-OFF cycle. This may be omitted if there is no second
cadence.
Second Signal Off Time [10 msec] – The “Signal Off” period (in 10 msec units)
for the second cadence ON-OFF cycle. This may be omitted if there is no second
cadence.
Third Signal On Time [10 msec] – The “Signal On” period (in 10 msec units) for
the third cadence ON-OFF cycle. This may be omitted if there is no third
cadence.
Third Signal Off Time [10 msec] – The “Signal Off” period (in 10 msec units) for
the third cadence ON-OFF cycle. This may be omitted if there is no third
cadence.
Fourth Signal On Time [10 msec] – The “Signal On” period (in 10 msec units)
for the fourth cadence ON-OFF cycle. This may be omitted if there is no fourth
cadence.
Fourth Signal Off Time [10 msec] – The “Signal Off” period (in 10 msec units)
for the fourth cadence ON-OFF cycle. This may be omitted if there is no fourth
cadence.