37.5.1.6.5 Action/Event
Action/Event is the name of the table's events that are the possible triggers for the
entire protocol state machine. They can be selected from the list of events in the
CASSetup.h file (e.g., EV_DISCONNECT_INCOMING).
At the beginning of the state, there can be up to four special unconditional
Action/Events called FUNCTION. These events are functions that are unconditionally
performed when the table reaches the state. These actions are labeled FUNCTION0
to FUNCTION3.
The following is the list of available protocols table actions (events to the state
machine):
User Command Oriented:
EV_PLACE_CALL - When initiating a new outgoing call
EV_ANSWER - When answering an incoming call
EV_DISCONNECT_OUTGOING - When disconnecting outgoing call.
EV_DISCONNECT_INCOMING - When disconnecting incoming call.
EV_RELEASE_CALL - When releasing a call
EV_USER_BLOCK_COMND - When using blocking/unblocking a channel.
EV_MAKE_METERING_PULSE - When starting the metering pulse while
using the SET_PULSE_TIMER function to start the timer to get the Off event
(refer to the EV_METERING_TIMER_PULSE_OFF below.).
EV_METERING_TIMER_PULSE_OFF - event after timer
(SET_PULSE_TIMER function) expires.
EV_MAKE_FLASH_HOOK - When a flash hook is triggered.
CAS Change Oriented:
EV_CAS_1_1 - a new CAS A,B bits are received (A=1, B=1, was stable for
the bouncing period).
EV_CAS_1_0 - a new CAS A,B bits are received (A=1, B=0, was stable for
the bouncing period).
EV_CAS_0_1 - a new CAS A,B bits are received (A=0, B=1, was stable for
the bouncing period).
EV_CAS_0_0 - a new CAS A,B bits are received (A=0, B=0, was stable for
the bouncing period).
Timer Oriented:
EV_TIMER_EXPIRED1 - timer 1 that was previously set by table has
expired.
EV_TIMER_EXPIRED2 - timer 2 that was previously set by table has
expired.
EV_TIMER_EXPIRED3 - timer 3 that was previously set by table has
expired.
EV_TIMER_EXPIRED4 - timer 4 that was previously set by table has
expired.
EV_TIMER_EXPIRED5 - timer 5 that was previously set by table has
expired.
EV_TIMER_EXPIRED6 - timer 6 that was previously set by table has

Table of Contents