Installation & Operation Manual 492 Document # LTRT-92224
Mediant 8000
Parameter Name Type
Provisioning
Type
Description
MSU Window Integer
0-255
Offline Defines the number of Message Signal
Units (MSUs) on a congested routeset
between 2 congestion indications.
SS7 Node
Timers ID
Integer
1-3
Offline Defines the ID of the SS7 Node Timers
profile that contains timers and basic
MTP3 layer configuration for specific SS7
Node.
Multiple SS7 Nodes can use the same
SS7 Node Timers profile.
ISUP Layer 4
App
Enum
None, Ual
Offline Defines the Layer 4 application to which
the ISUP messages are transferred.
For example: to transfer an ISUP payload
to the MGC via M3UA link, define this
parameter as UAL.
If the payload-specific Layer 4 App equals
none, the payload is discarded.
SCCP Layer 4
App
Enum
None, Ual
Offline Defines the Layer 4 application to which
the SCCP messages are transferred.
BISUP Layer 4
App
Enum
None, Ual
Offline Defines the Layer 4 application to which
the BISUP messages are transferred.
ALCAP Layer 4
App
Enum
None, Ual, Alcap
Offline Defines the Layer 4 application to which
the ALCAP messages are transferreds.
None ALCAP payload is discarded
UAL ALCAP payload is forwarded to
the remote entity via UAL
ALCAP ALCAP payload is locally
processed on the Media Gateway
board