c. In the Navigation pane, select PSTN Sigtran UAL Groups; The UAL
Group list is displayed.
d. Use the
or buttons to add or remove entries.
e. Select a specific row and then in the configuration pane, click UAL Group
Settings; The UAL Group Settings screen is displayed.
f. Configure the UAL Group properties according to the table 'UAL Group
Properties'. Make sure to configure Protocol Type as M3UA and attach the
corresponding SS7 Node and M3UA Routing Group.
9. Bring all of the configured entities into service.
a. Click
to access the Media Gateway Status screen.
b. In the Navigation pane, select PSTN and then select the corresponding SS7
Node.
c. In the Actions bar, click Recursive Unlock.
Note: Instead of performing the Recursive Unlock operation on SS7 Node, you
may also perform a regular Unlock operation on all the newly added SS7 Data
Links.
10. In the Navigation pane, select the the newly associated Media Gateway board.
a. If the Media Gateway board is not already unlocked, in the Actions bar, click
Unlock. Wait until the board completes the restart and its Operational State
changes to Enabled (board will be color-coded Green in the EMS).
b. In the Navigation Pane, select PSTN
Sigtran UAL Groups.
c. Unlock all of the UAL Groups configured in Step 8 by clicking Unlock in the
Actions bar. This step may be skipped if you previously unlocked the Media
Gateway board, as UAL Groups are automatically unlocked as part of the
Media Gateway Board's Unlock action.
11. Perform the corresponding configuration on the Signaling Gateway and/or
Softswitch to which the Mediant 8000 is connected. Bring all configured entities in
service.
12. On the Mediant 8000, verify that the Operational State of all configured entities
(i.e. SS7 Node, SS7 Linkset, SS7 Routeset, SS7 Data Link, UAL Group and
E1/T1 Trunk) is Enabled.