EasyManua.ls Logo

AudioCodes Mediant 8000 - Page 531

AudioCodes Mediant 8000
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 6.6 531 October 2014
Installation & Operation Manual 39. Configuring the Media Settings
Parameter Name Type Provisioning Type Description
Echo Canceller Type Enum
Line,Acoustic
Instant Defines the echo
canceller type.
Line echo canceller
= Echo canceller for
Tel side (default)
Acoustic echo
suppressor = Echo
canceller for IP side
Attenuation Intensity Integer
0-3
Instant Defines the acoustic
echo suppressor
signals identified as
echo attenuation
intensity.
Max ERL Threshold -
DB
Integer
0-60
Instant Defines the acoustic
echo suppressor
maximum ratio between
signal level and
returned echo from the
phone (in decibels).
Min Reference Delay
x10 msec
Integer
0-40
Instant Defines the acoustic
echo suppressor
minimum reference
delay (in 10-ms units).
Max Reference Delay
x10 msec
Integer
0-40
Instant Defines the acoustic
echo suppressor
maximum reference
delay (in 10-ms units).

Table of Contents