Version 6.6 847 October 2014
Installation & Operation Manual 49. Collecting Advanced Media Gateway Board Logs
Advanced Debug level -This option is recommended when the device runs under
"heavy" traffic (debug level 7). In this mode:
The Syslog debug level automatically changes between Debug level,and
Warning level and Emergency level, depending on the device's CPU
consumption so that VoIP traffic isn’t affected.
Syslog messages are bundled into a single UDP packet, after which they are
sent to a Syslog server (bundling size is determined by the
'MaxBundleSyslogLength' parameter). Bundling reduces the number of UDP
Syslog packets, thereby improving CPU utilization.
You can configure these Debug levels for SIP messages globally for all SIP boards (
by setting 'SIP Logging Level' in the gateway level Troubleshooting screen) or disable
the sending of SIP messages to the Syslog server entirely by setting the parameter
'Apply SIP Logging Level' to 'Disable'.
Alternatively, you can configure the Debug level for each individual board by setting
'SIP Syslog Logging Level' (in the board level Troubleshooting screen) or disable the
sending of SIP messages entirely by configuring the same parameter 'SIP Syslog
Logging Level' to 'DebugDisable'.
Note: If you configure the debug level globally after you have already configured
the debug level for a specific board or you later configure it, then the board
configuration applies.