Version 6.6 865 October 2014
Installation & Operation Manual 51. Collecting Traces from the Ethernet Switch Board’s Mirror Port
Parameter Name Type Provisioning Type Description
TOS Integer
-1 to 63
Online Defines the value of the "Type Of Service"
element in the packet’s IP header (bits
153-160). The value must be specified in
decimal format.
When set to ‘n’, matches all element
values.
Packet Length
Integer
-1 to 65535
Online Defines the value of the "Packet Length"
element in the packet’s IP header (bits
161-176). The value must be specified in
decimal format.
When set to -1, matches all element
values.
ID Number Integer
-1 to 65535
Online Defines the value of the "Identification"
element in the packet’s IP header (bits
177-192). The value must be specified in
decimal format.
When set to -1, matches all element
values.
Fragment Flag
Integer
-1 to 7
Online Defines the value of the "Fragment Flag"
element in the packet’s IP header (bits
193-195). The value must be specified in
decimal format. When set to -1, matches
all element values.
Fragment Offset Integer
-1 to 8191
Online Defines the value of the "Fragment Offset"
element in the packet’s IP header (bits
196-208). The value must be specified in
decimal format. When set to -1, matches
all element values.
Flags Online Defines the value of the "Flags" element in
the packet’s IP header (bits 193-208). The
value must be specified in decimal format.
When set to -1, matches all element
values.
TTL
Integer
-1 to 255
Online Defines the value of the "Time To Live"
element in the packet’s IP header (bits
209-216). The value must be specified in
decimal format.
When set to -1, matches all element
values.