Version 6.6 883 October 2014
Installation & Operation Manual A. Examples of IP Network Connectivity Configuration
7. Configure the Media Gateway's board’s IP Addresses:
modify moBoard#11/moBoardIPAddress#1=10.8.1.20
modify moBoard#12/moBoardIPAddress#1=10.8.1.21
modify moBoard#13/moBoardIPAddress#1=10.8.1.22
modify moBoard#14/moBoardIPAddress#1=10.8.1.23
8. Activate the new network configuration by unlocking the Media Gateway:
SC-1 -- ~ -- /moGW
unlock
Performing unlock action on /moGW - OK!
The new network configuration will be activated. The Media Gateway boards will
be reset and their Operational State will be changed to Disabled (boards will be
displayed as Red in the EMS GUI).
It may take up to 5 minutes for all Media Gateway boards to complete the restart.
When the Media Gateway board returns to service, its Operational State will be
changed to Enabled and the board's color will be displayed as Green in the EMS
GUI.
9. If interface separation of VLAN Tags configuration was changed, you will be
asked to reset (lock/unlock) the ES boards prior to performing the unlock action
on the Media Gateway. In such case, do the following:
a. Lock both ES boards:
SC-1 -- ~ -- /moGW
lock esboard#9
Do you really want to lock /moGW/moSwitchBoard#9? [y/n] y
Performing lock action on /moGW/moSwitchBoard#9 - OK!
lock esboard#19
Do you really want to lock /moGW/moSwitchBoard#19? [y/n] y
Performing lock action on /moGW/moSwitchBoard#19 - OK!
b. Unlock the ES board in slot 9:
SC-1 -- ~ -- /moGW
unlock esboard#9
Performing unlock action on /moGW/moSwitchBoard#9 - OK!