ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 4 May 2002
10-245 555-233-123
Table 10-98. ATM Board Reset (#1256)
Error
Code
Tes t
Result Description/Recommendation
1005 ABORT Wrong circuit pack configuration to run this test. The ATM CES
Trunk Interface circuit pack provides timing for the system and
cannot be reset without major system disruptions.
Set synchronization to another ATM CES trunk circuit pack or to
the Tone-Clock circuit pack and test again.
1015 ABORT Test cannot be run because the ATM-TRK circuit pack has not
been busied out.
Busyout out the circuit pack (busyout board UUCSS).
Repeat the test (test board UUCSS long).
None ABORT Could not allocate the required system resources
Retry the command up to 5 times at 1-minute intervals.
If the test continues to abort escalate the problem.
2000 ABORT Sanity test timed out.
Wait 5 minutes. Then see if ATM-TRK circuit pack is visible to the
system by running list configuration all.
If the ATM-TRK circuit pack is visible (list configuration all), run
the test again, and escalate if the problem recurs.
If the ATM-TRK circuit pack is not visible to the system (list
configuration all), re-seat the ATM-TRK circuit pack, and retest.
If the ATM-TRK circuit pack is still not recognized by the system,
replace the board.
2100 ABORT Could not allocate required system resources
Retry the command up to 5 times at 1-minute intervals.
2500 ABORT Internal system error
Try to reset the circuit pack (reset board UUCSS).
Continued on next page