BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-295 555-233-123
Hardware Error Log Entries and Test to Clear
Val ues
Table 10-118. BRI-SET/ASAI-ADJ Error Log Entries
Error
Type
Aux
Data
Associated
Tes t
Alarm
Level
BRI-PORT
Alarm Level
ABRI-PORT
ATT-PORT
LGATE-PORT
ATTE-PT
On/
Off
Board Test to Clear Value
0
1
0 Any Any Any Any test BRI-SET or
ASAI-ADJ ATT-ADJ
LGATE-AJ ATTE-AJ
2(a) 2-10
2
None
18 0 busyout
station ext
WARNING MAJOR/
WARNING
2
OFF release station <ext>
130(b) WARNING ON test port PCSS sh
257(c) Any BRI Layer 3
Query
(#629)
WARNING MAJOR/
WARNING
2
OFF test station ext r 2
test data-module ext
r 2
351(d) 0 None WARNING OFF busyout and release
station
513(e) 0 None
769(f) 0 None WARNING MAJOR OFF
2561(g) 0 None
2562-
2566(h)
0 None
2567(o) 0 None
2568(p) 0 None
2817(i) 0 XID Test
(#628)
WARNING MAJOR/
WARNING
2
OFF test station ext r 2
test data-module ext
r 2
3073(j) 0 BRI
Remote
Loop Back
(#627)
WARNING OFF test station ext l r 2
test data-module ext
l r 2
3329(k) Any Signaling
Link Status
(626)
WARNING MAJOR/
WARNING
2
OFF †
Continued on next page