Maintenance Object Repair Procedures
555-233-123
10-296 Issue 4 May 2002
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol;
timers associated with certain Layer 3 messages have expired before a
required response was received. In the following table, the aux data field
indicates which timer has just expired. (For more information, refer to the
Avaya ISDN-BRI Specification.)
The switch sent a message to the endpoint which did not respond in the
allotted time. This can happen occasionally due to failure of the
point-to-point signaling link or because of a problem in the BRI endpoint or
3584 0, 1 None
3585-
3839(i)
0 None
3840-
4095
(m) (n)
0 None
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2 Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
Aux Data Timer Type
2 First T303 (SETUP timer)
3 Second T303 (SETUP timer)
4 T305 (DISConnect timer)
5 First T308 (RELease timer)
6 Second T308 (RELease timer)
10 T316 (RESTart timer)
12 T309 (Layer 2 Failure timer)
16 TM100 (Management Information Message timer 1)
17 TM200 (Management Information Message timer 2)
102 TASAI (ASAI Routing Timer)
Table 10-118. BRI-SET/ASAI-ADJ Error Log Entries — Continued
Error
Type
Aux
Data
Associated
Tes t
Alarm
Level
BRI-PORT
Alarm Level
ABRI-PORT
ATT-PORT
LGATE-PORT
ATTE-PT
On/
Off
Board Test to Clear Value
Continued on next page