BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-319 555-233-123
Table 10-126. TEST #630 BRI Set Audits
Error
Code
Te s t
Result Description/Recommendation
1113 ABORT The signaling link between the switch and the endpoint is
down.
1. Use the test port PCSSpp long command to clear any
errors which prevent establishment of the signaling link.
2. Examine the results of the Signaling Link Status Test
(#626) which is run as part of this command. If this test
aborts or fails, follow the repair procedure for Test #626.
3. If the BRI Set Audits test continues to abort, escalate the
problem.
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack)
Maintenance documentation.
1144 ABORT The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the
PPN.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
Continued on next page