Maintenance Object Repair Procedures
555-233-123
10-346 Issue 4 May 2002
Aux Data:
c. Error Type 1025: Maintenance cycle detects broken directory in memory
card.
NOTE:
If the maintenance cycle detects a broken directory, then the switch
raises an off-board MINOR alarm.
1. Make sure that the “card-in-use” amber LED is not glowing.
2. Remove the memory card from the Processor circuit pack slot.
3. Insert a new memory card firmly into the Processor circuit pack slot.
4. Verify the new memory card function (test card-mem).
Aux Data:
101 System-upgrade memory card
102 Uses announcement feature, without available announcement file
103 System-upgrade memory card, and uses announcement feature
without available announcement file
116 Memory card capacity does not match system configuration
118 Uses announcement feature without available announcement file, and
memory card capacity does not match system configuration
132 System translation reaches 98% capacity
134 Uses announcement feature without available announcement file, and
system translation reaches 98% capacity
148 Memory card capacity does not match system configuration, and
system translation reaches 98% capacity
150 Uses announcement feature without available announcement file,
memory card capacity does not match system configuration, and
system translation reaches 98% capacity
104 Memory card directories are corrupt and irrecoverable
105 Cannot write “0” into memory card before an erase operation
106 Cannot erase memory card
107 Cannot write data into a memory card after an erasure
108 Cannot turn on 12-Volt power supply for directory recovery