EasyManua.ls Logo

Avaya Definity SI - Page 1195

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CLAN-BD (Control LAN Circuit Pack)
Issue 4 May 2002
10-409 555-233-123
Link Status Test (#601)
This non-destructive test determines the state of the call control signaling link for
Control LANs. If the signaling link is physically connected, the test sends a test
frame over the link and checks for a response. The test passes only if both the
signaling link is connected and the test frame is successfully transmitted.
A failure may indicate a problem with:
This circuit pack
The packet bus
The packet interface circuit pack
Table 10-153. TEST #601 Link Status Test
Error
Code
Tes t
Result Description/Recommendation
1125 ABORT RSCL link or C-LAN board not in service.
1. Release the board.
2. Repeat the test.
3. Escalate if the problem persists.
2012 ABORT Could not allocate the necessary system resources to run this
test.
2100 ABORT Internal system error.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
Continued on next page

Table of Contents

Related product manuals