Maintenance Object Repair Procedures
555-233-123
10-410 Issue 4 May 2002
2 FAIL The RSCL control link disconnected.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the test continues to fail, execute the Packet Interface Test
(#598) (test board UUCSS) to determine if the problem is
due to the circuit pack.
3. If the Packet Interface Test (#598) fails, refer to Packet
Interface Test repair procedures.
4. If the Packet Interface Test (#598) passes, refer to Packet
Control Circuit Pack and Packet Bus repair procedures.
3 FAIL Received no response to RSCL control link test frame.
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
UUCSS).
3. If test continues to fail, replace the circuit pack.
PASS RSCL control link connected.
Table 10-153. TEST #601 Link Status Test Continued
Error
Code
Tes t
Result Description/Recommendation