Maintenance Object Repair Procedures
555-233-123
10-466 Issue 4 May 2002
If more than one CONFIG error is logged with an Aux Data of 1 at the same
time, investigate any EXP-INTF (Expansion Interface) errors before
proceeding.
Once the Port circuit pack location has been determined from Table
10-171, use the list configuration all command to determine if the circuit
pack is inserted. If not, insert the pack. If the circuit pack has already been
inserted but the error persists, replace the circuit pack.
Table 10-171. System Configuration Error Log Entries
Error Type Aux Data Port Circuit Pack Location
10 GAMUT Circuit Pack
1
11 GAMUT Circuit Pack
1
20 1E01
21 2E01
22 3E01
30 1E02
31 2E02
32 3E02
40 1E03
41 2E03
42 3E03
50 1E04
51 2E04
52 3E04
60 1E05
61 2E05
62 3E05
70 1E06
71 2E06
72 3E06
80 1E07
81 2E07
82 3E07
90 1E08
91 2E08
Continued on next page