Maintenance Object Repair Procedures
555-233-123
10-482 Issue 4 May 2002
4. Reset the selected DATA-CHL (test data-module ext long), using
DATA-CHL using its extension.
!
WARNING:
This command drops all data channel extensions. See DATA-CHL
(Data Channel) Maintenance documentation first.
5. If the problem persists, replace the TN2401/TN794 NetPkt or
TN777B Netcon circuit pack.
b. Error Type 23: Circuit pack is logically administered but not physically
installed.
1. Install the circuit pack.
2. Verify that alarm clears.
c. Error Type 257: Transient communications problems with circuit pack.
This error is not service-affecting and requires no action.
d. Error Type 513: Circuit pack reported hardware failure
1. Install the circuit pack.
2. Verify that alarm clears.
e. Error Type 769: While not important an important error, it can signal other
errors.
1. Look for other errors on this circuit pack.
f. Error Type 1025: This error is not service-affecting and requires no action.
g. Error Type 1: DATA-BD portion of the TN2401/TN794 NetPkt or TN777B
Netcon circuit pack not functioning.
Cannot reset TN2401/TN794 NetPkt or TN777B Netcon circuit pack with
usual command (reset board PCSS). Use Data Channel Reset Test
(#107) in the Long Test Sequence for the data channels to reset.
1. Determine how many data channels are administered (list data).
NOTE:
A data channel is identified by a type value of netcon.
2. Administer a data channel as necessary (add data-module [
ext |
next]).
3. Select a data channel from the list (list data).